EXAMPLE TWO
*AST798X*
Symbology Code 39
Desired Output: The input record must be Code 39 and be exactly seven
characters in length with the seventh character being an “X”. It is divided into
three fi elds; the fi rst three characters, the next three characters, and the last
character. The output should reverse the order of the fi rst two fi elds, delete
the last character, and add an F1 function code at the end of each fi eld. In
addition, a time delay of 900 milliseconds should be added between the fi elds
(after the F1) and another delay of 2000 milliseconds added to the end of the
record.
Formula ID e LEN 07 07 M 07 X C 03 C 03 A <F1>
SEND BD DLY 09 AD DLY 20
Field List Field A AST
Field B 798
Field C X
Field D <F1>
Prior to data editing, enable the Function Code Selection on page 9.
Keystroke Sequence
Enter Data Editing Setup /E/D/FJ<ENTER>
Enter Data Editing and Enable JA<ENTER>1<ENTER>
Enter Code ID and e (for Code 39) JC<ENTER>e<ENTER>
Enter Length and 0707 JD<ENTER>0<ENTER>7<ENTER>0
< ENTER >7<ENTER>
Enter Match and 07X JE<ENTER>0<ENTER>7<ENTER>
X<ENTER>
Enter Count and 03 JF<ENTER>0<ENTER>3<ENTER>
Enter Count and 03 JF<ENTER>0<ENTER>3<ENTER>
Enter Add Field & <F1> character JJ<ENTER>\F1<ENTER>
Enter Field Sequence and BD JK<ENTER>B<ENTER>D<ENTER>
Enter Add Delay and 09 JK<ENTER>JM<ENTER>0<ENTER>
9<ENTER>
Enter Field Sequence and AD JK<ENTER>A<ENTER>D<ENTER>
Enter Add Delay and 20 JK<ENTER>JM<ENTER>2<ENTER>
0<ENTER>
Enter Exit Setup JZ<ENTER>
Output Data 798<<F1>>.9s delay AST<<F1>>
2s delay
43