24
Read Two-Digit Addendum
If enabled, the reader will decode the two-digit secondary symbol when it is
scanned with the primary symbol, and add the data to the end of the transmis-
sion. If not, any two-digit secondary symbol will be ignored.
SELECTION CODE: G1
Read Two-Digit Addendum K
Do Not Read Two-Digit Addendum L
Read Five-Digit Addendum
This option operates in the same manner as the Read Two Digit Addendum
option except it enables the reading of a five digit secondary symbol.
SELECTION CODE: G1
Read Five-Digit Addendum M
Do Not Read Five-Digit Addendum N
Addendum Required
If a two or five-digit addendum is enabled, then enabling this option will
require an addendum be present before a good read is registered. If not, then
symbols with and without the addendum will be accepted.
SELECTION CODE: G1
Addendum Required O
Addendum Not Required P
Add Separator Space
This option is used with the Two and Five-Digit Addendum options. If en-
abled, an ASCII space character is inserted between the data decoded from
the primary UPC symbol and the addendum symbol.
SELECTION CODE: G1
Add Space Separator Q
Not Add Space Separator R
Convert UPC-A to EAN-13
SELECTION CODE: G1
Do Not Convert to EAN-13 S
Convert to EAN-13 T